DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ALICO(SITEA)HE-1023563287818964

Start Test Date:25-JAN-1988 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):
Discharge Rate (gal/min):1171Horizontal K (ft/day):1365
Hours Pumped:76.6Vertical K (ft/day):
Tested Interval Min. (ft BLS):92Storativity:.00031
Tested Interval Max. (ft BLS):182Leakance (1/day):
No. Monitored Wells:4Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:HAND TAPED WELLS EVERY 2 HOURS AS CHECK ON DAS - VARIATION <.1 FT. INFLUENCING FACTORS: DISCHARGE CANAL ~500 FT FROM WELLS, WATER LEVEL ROSE IN CANAL THROUGHOUT TEST. WHIP: INTERMEDIATE WELLS WOULDN'T RUN IN PROGRAM

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HE-1028
563306
818812
COOPER-JACOB APPROXIMATION
101.7
1.85
113541
.0055
HE-1029
563306
818812
COOPER-JACOB APPROXIMATION
99.75
2.27
125450
.00015
HE-1025
563006
819259
COOPER-JACOB APPROXIMATION
200.8
1.8
113541
.0012
HE-1026
563006
819259
COOPER-JACOB APPROXIMATION
202.6
1.96
122873
.00031

Page generated at: 04-OCT-2025 11:44 EDT