DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ALICO(SITEC)HE-1035633623800989

Start Test Date:17-AUG-1987 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):33422
Discharge Rate (gal/min):343Horizontal K (ft/day):668
Hours Pumped:76.4Vertical K (ft/day):.000267
Tested Interval Min. (ft BLS):70Storativity:.000058
Tested Interval Max. (ft BLS):120Leakance (1/day):.0000067
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HE-1037
633563
801640
COOPER-JACOB APPROXIMATION
104.5
1.64
31846
.00009
.000003
HE-1039
633633
800989
COOPER-JACOB APPROXIMATION
195
1.52
32842
.000019
.00000086
HE-1040
633633
800989
COOPER-JACOB APPROXIMATION
47.25
1.94
37533
.000065
.000017

Page generated at: 04-OCT-2025 03:58 EDT