DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BARRON COLLIERHE-1041593482741053

Start Test Date:18-MAY-1987 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):60963
Discharge Rate (gal/min):760Horizontal K (ft/day):1524
Hours Pumped:72Vertical K (ft/day):2.25
Tested Interval Min. (ft BLS):40Storativity:.01
Tested Interval Max. (ft BLS):80Leakance (1/day):.0012
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:DISCHARGE TO LAND SURFACE TO EAST - WATER PONDED ~800' FROM PW.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HE-1042
593249
740527
COOPER-JACOB APPROXIMATION
76.6
1.99
60958
.00021
.0013
HE-1045
566935
745547
COOPER-JACOB APPROXIMATION
200.8
1.64
61279
.00012
.0014

Page generated at: 04-OCT-2025 10:21 EDT