DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CARL GALLAGHERHE-1054623955747081

Start Test Date:27-FEB-1987 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):88235
Discharge Rate (gal/min):869Horizontal K (ft/day):2941
Hours Pumped:72.5Vertical K (ft/day):1.6
Tested Interval Min. (ft BLS):70Storativity:.0005
Tested Interval Max. (ft BLS):100Leakance (1/day):.04
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HE-1056
623955
747081
COOPER-JACOB APPROXIMATION
250.9
.83
88164
.00021
.014
HE-1057
651692
767361
COOPER-JACOB APPROXIMATION
100.5
.88
100096
.00033
.016
HE-1058
651692
767361
COOPER-JACOB APPROXIMATION
54.5
1.09
88752
.00071
.048

Page generated at: 28-SEP-2024 21:34 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?