DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
COLLIER CORP. (S31 T46 R32)HE-289601629763936

Start Test Date:18-JUN-1958 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):68182
Discharge Rate (gal/min):1570Horizontal K (ft/day):758
Hours Pumped:14Vertical K (ft/day):.000000043
Tested Interval Min. (ft BLS):Storativity:.000015
Tested Interval Max. (ft BLS):70Leakance (1/day):
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY T.P. 88-12
Comments:

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HE-290
593481
740652
COOPER-JACOB APPROXIMATION
1800
1.41
66845
.00016
HE-291
593481
740652
COOPER-JACOB APPROXIMATION
2300
1.21
68850
.00015

Page generated at: 28-SEP-2024 22:23 EDT