DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-DZMW1863957578629

Start Test Date:12-APR-2010 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):22Horizontal K (ft/day):2.12
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1900Storativity:
Tested Interval Max. (ft BLS):1940Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 22340: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 56



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-DZMW1863957578629

Start Test Date:25-APR-2010 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):12Horizontal K (ft/day):.3
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2210Storativity:
Tested Interval Max. (ft BLS):2260Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 31860: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 92

Page generated at: 04-OCT-2025 08:22 EDT