DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:08-DEC-2009 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):15Horizontal K (ft/day):.55
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1839Storativity:
Tested Interval Max. (ft BLS):1856Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 6360: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 175



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:09-DEC-2009 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):15.5Horizontal K (ft/day):.57
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1899Storativity:
Tested Interval Max. (ft BLS):1916Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 16100: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 159



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:12-DEC-2009 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):11Horizontal K (ft/day):.49
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1973Storativity:
Tested Interval Max. (ft BLS):1991Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 26833: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 136



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:26-JAN-2010 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):0.5Horizontal K (ft/day):.05
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2234Storativity:
Tested Interval Max. (ft BLS):2251Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 35333: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 21



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:28-JAN-2010 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6Horizontal K (ft/day):.48
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2399Storativity:
Tested Interval Max. (ft BLS):2417Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 26367: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 73



SitePumped WellX-Coord(ft)Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELDHHRO-IW1863971578545

Start Test Date:29-JAN-2010 0000Aquifer:
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):8Horizontal K (ft/day):.79
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2639Storativity:
Tested Interval Max. (ft BLS):2657Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:TDS = 37700: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 58

Page generated at: 04-OCT-2025 11:42 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?