DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELD
HHRO-IW2
863918
578699
Start Test Date:
21-DEC-2009 0000
Aquifer:
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
5.5
Horizontal K (ft/day):
.37
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1884
Storativity:
Tested Interval Max. (ft BLS):
1901
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:
TDS = 13910: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 143
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELD
HHRO-IW2
863918
578699
Start Test Date:
08-FEB-2010 0000
Aquifer:
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
22
Horizontal K (ft/day):
1.11
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2049
Storativity:
Tested Interval Max. (ft BLS):
2067
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:
TDS = 29000: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 110
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELD
HHRO-IW2
863918
578699
Start Test Date:
09-FEB-2010 0000
Aquifer:
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
30
Horizontal K (ft/day):
2.02
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2569
Storativity:
Tested Interval Max. (ft BLS):
2587
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:
TDS = 36467: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 86
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
HIALEAH HEIGHTS REVERSE OSMOSIS WELLFIELD
HHRO-IW2
863918
578699
Start Test Date:
11-FEB-2010 0000
Aquifer:
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
1
Horizontal K (ft/day):
.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2259
Storativity:
Tested Interval Max. (ft BLS):
2277
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
SWS, City of Hialeah Reverse Osmosis Water Treatment Plant Injecion Wells IW-1 & IW-2 and Dual-zone Monitor Well DZMW-1 Completion Report. Nov. 12, 2010
Comments:
TDS = 35900: Reporting hydraulic conductivity from recovery analysis: Maximum drawdown [ft] = 63
Page generated at: 04-OCT-2025 08:25 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?