DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):28.7
Discharge Rate (gal/min):70Horizontal K (ft/day):1.76
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1354Storativity:
Tested Interval Max. (ft BLS):1370Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24-HOUR INJECTION TEST PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN IS 2.6646

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
96.5
42.6



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):68.7
Discharge Rate (gal/min):73Horizontal K (ft/day):4.25
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1404Storativity:
Tested Interval Max. (ft BLS):1420Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24-HOUR INJECTION TEST PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN IS 5.9528

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
43.2
95.4



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):16.4
Discharge Rate (gal/min):30Horizontal K (ft/day):.99
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1769Storativity:
Tested Interval Max. (ft BLS):1785Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = 1.0772

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
77
17.6



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0300Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2.03
Discharge Rate (gal/min):6.4Horizontal K (ft/day):.12
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1894Storativity:
Tested Interval Max. (ft BLS):1910Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .1077

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
144.5
1.74



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0400Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):8.81
Discharge Rate (gal/min):27Horizontal K (ft/day):.51
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1959Storativity:
Tested Interval Max. (ft BLS):1975Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .5669

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
132.2
9.1



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0500Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):3.93
Discharge Rate (gal/min):12Horizontal K (ft/day):.25
Hours Pumped:Vertical K (ft/day):.2409
Tested Interval Min. (ft BLS):2046Storativity:
Tested Interval Max. (ft BLS):2062Leakance (1/day):
No. Monitored Wells:16Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .2522

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
135
4.01



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLANHOL-IW1941047616692

Start Test Date:25-DEC-2000 0600Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):25.9
Discharge Rate (gal/min):61Horizontal K (ft/day):1.59
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2193Storativity:
Tested Interval Max. (ft BLS):2209Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = 1.3900

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HOL-IW1
941047
616692
COOPER-JACOB APPROXIMATION
119
22.3

Page generated at: 28-SEP-2024 19:16 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?