DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 0900
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
681.3
Discharge Rate (gal/min):
77
Horizontal K (ft/day):
36.85
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1390
Storativity:
Tested Interval Max. (ft BLS):
1400
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = 6.2362
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
31
271.7
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
63.7
Discharge Rate (gal/min):
77
Horizontal K (ft/day):
3.4
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1510
Storativity:
Tested Interval Max. (ft BLS):
1528
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = 5.1024
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
56
5.88
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
5.28
Discharge Rate (gal/min):
16
Horizontal K (ft/day):
.28
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1760
Storativity:
Tested Interval Max. (ft BLS):
1778
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .3118
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
129
.53
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
4.34
Discharge Rate (gal/min):
34
Horizontal K (ft/day):
.96
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1810
Storativity:
Tested Interval Max. (ft BLS):
1828
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = 1.0205
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
87
1.34
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1300
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
3.25
Discharge Rate (gal/min):
9
Horizontal K (ft/day):
.17
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2093
Storativity:
Tested Interval Max. (ft BLS):
2111
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .1729
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
125
3.21
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1400
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
17.3
Discharge Rate (gal/min):
33
Horizontal K (ft/day):
.94
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2265
Storativity:
Tested Interval Max. (ft BLS):
2283
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .8504
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
103
15.2
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1500
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
11.4
Discharge Rate (gal/min):
23
Horizontal K (ft/day):
.62
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2300
Storativity:
Tested Interval Max. (ft BLS):
2318
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .6236
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
100
11.6
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF HOLLYWOOD-SOUTHERN REGIONAL WASTEWATER TRTMT PLAN
HOL-IW2
940929
616415
Start Test Date:
25-DEC-2000 1600
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
16.4
Discharge Rate (gal/min):
24
Horizontal K (ft/day):
.91
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2410
Storativity:
Tested Interval Max. (ft BLS):
2428
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HAZEN AND SAWYER. 2003. REQUEST FOR 24 HOUR INJECTION TEST, PERMIT NUMBER 156419-001-UC.
Comments:
PARAMETER VALUES ARE FROM RECOVERY METHOD OF ANALYSIS. HORIZONTAL K FOR DRAWDOWN = .7654
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
HOL-IW2
940929
616415
COOPER-JACOB APPROXIMATION
86
14
Page generated at: 04-NOV-2024 16:26 EDT