DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:19-SEP-1994 0000Aquifer:LOWER HAWTHORN CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):91
Discharge Rate (gal/min):20Horizontal K (ft/day):1.65
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):495Storativity:
Tested Interval Max. (ft BLS):550Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 0.34 GPM/FT; T ESTIMATED FROM SPECIFIC CAPACITY

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:20-SEP-1994 0000Aquifer:INTERMEDIATE AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):94Horizontal K (ft/day):
Hours Pumped:1Vertical K (ft/day):
Tested Interval Min. (ft BLS):654Storativity:
Tested Interval Max. (ft BLS):710Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 1.59 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:10-DEC-1994 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):102Horizontal K (ft/day):
Hours Pumped:1.7Vertical K (ft/day):
Tested Interval Min. (ft BLS):1851Storativity:
Tested Interval Max. (ft BLS):1901Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 13.49 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:19-DEC-1994 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):100Horizontal K (ft/day):
Hours Pumped:1.7Vertical K (ft/day):
Tested Interval Min. (ft BLS):2195Storativity:
Tested Interval Max. (ft BLS):2251Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 9.38 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:21-DEC-1994 0000Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):102Horizontal K (ft/day):
Hours Pumped:1Vertical K (ft/day):
Tested Interval Min. (ft BLS):1469Storativity:
Tested Interval Max. (ft BLS):1524Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 15.13 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:30-DEC-1994 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):67Horizontal K (ft/day):
Hours Pumped:1.3Vertical K (ft/day):
Tested Interval Min. (ft BLS):1158Storativity:
Tested Interval Max. (ft BLS):1185Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 1.45 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
I75-TWI75-TW416564668291

Start Test Date:25-FEB-1995 0000Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):48Horizontal K (ft/day):
Hours Pumped:1Vertical K (ft/day):
Tested Interval Min. (ft BLS):1287Storativity:
Tested Interval Max. (ft BLS):1318Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., December 2001, HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM AT THE I-75 CANAL SITE COLLIER COUNTY, FLORIDA Technical Publication WS-79
Comments:SPECIFIC CAPACITY = 1.21 GPM/FT

Page generated at: 04-OCT-2025 06:45 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?