DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
APT site for pumped well at IR-26F
IR-26F
763135
1181384
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
OTHER
Transmissivity (ft2/day):
38558
Discharge Rate (gal/min):
1000
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
350
Storativity:
Tested Interval Max. (ft BLS):
900
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Data compiled in SFWMD TP 92-03, originally from, SCHINER, G.R., C.P. LAUGHLIN AND D.J. TOTH. 1988. GEOHYDROLOGY OF INDIAN RIVER COUNTY, FL. USGS WRIR 88-4073.
239
Comments:
TRANSMISSIVITY ESTIMATED BY SPECIFIC CAPACITY FIT TO REGRESSION CURVE SPECIFIC CAPACITY = 200 GPM/FT DRAWDOWN = 5 FT ESTIMATED MINIMUM TEST INTERVAL
Page generated at: 04-OCT-2025 06:54 EDT