DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELL
IWSD-TW
514986
756313
Start Test Date:
22-FEB-1996 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
108
Horizontal K (ft/day):
Hours Pumped:
1.3
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1876
Storativity:
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
BENNETT, TECH PUB. WS-14, SFWMD, MAY 2002, HYDROLOGIC INVESTIGATION OF FAS- IMMOKALEE WATER & SEWER DISTRICT WWTP, MAY 2002
11
Comments:
STRADDLE PACKER TEST 1 OF 2 TEST CONDUCTED FOR WATER QUALITY AND TO DETERMINE BASE OF USDW
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELL
IWSD-TW
514986
756313
Start Test Date:
26-FEB-1996 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
32
Horizontal K (ft/day):
Hours Pumped:
2.25
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1700
Storativity:
Tested Interval Max. (ft BLS):
1774
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
BENNETT, SFWMD, TECH PUB WS-14, MAY 2002, HYDROGEOLOGIC INVESTIGATION OF THE FAS- IMMOKALEE WATER & SEWER DISTRICT WWTP, MAY 2002
11
Comments:
STRADDLE PACKER TEST 2 OF 2 TEST CONDUCTED FOR WATER QUALITY AND TO DETERMINE BASE OF USDW
View Water Quality Results for the Above Test
Page generated at: 04-OCT-2025 08:39 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?