DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SANCARLOS - ASR
L-5812
402977
748030
Start Test Date:
10-NOV-1999 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
70000
Discharge Rate (gal/min):
985
Horizontal K (ft/day):
Hours Pumped:
8
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
650
Storativity:
Tested Interval Max. (ft BLS):
701
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
C-J SOLUTION FOR DRAWDOWN IN SZMW-1R IS SUSPECT. SOLUTION IS FOR VERY LATE TIME ONLY, AND BACKGROUND CHANGES DUE TO PRIOR RECHARGE MAY HAVE AFFECTED RESPONSE.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
L-5814
402976
747828
COOPER-JACOB APPROXIMATION
200
5214
L-5814
402976
747828
THEIS RECOVERY
200
9358
Page generated at: 04-OCT-2025 06:39 EDT