SitePumped WellX-Coord(ft)Y-Coord (ft)
CORKSCREW WTP - ASRL-5855425771775262

Start Test Date:07-SEP-1995 0001Aquifer:MID-HAWTHORN AQUIFER
Test Type:APTTransmissivity (ft2/day):3410
Discharge Rate (gal/min):400Horizontal K (ft/day):49
Hours Pumped:115.5Vertical K (ft/day):
Tested Interval Min. (ft BLS):328Storativity:.000077
Tested Interval Max. (ft BLS):397Leakance (1/day):.000016
No. Monitored Wells:1Specific Capacity (gpm/ft):20.9
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:RECOMMENDED PARAMETERS FOR TRANSMISSIVITY AND STORATIVITY USE HANTUSH METHOD

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5858
425408
775264
COOPER-JACOB APPROXIMATION
400
3380
.000067
L-5858
425408
775264
HANTUSH (1960)
400
3410
.000077
.000016
L-5858
425408
775264
THEIS RECOVERY
400
3460



SitePumped WellX-Coord(ft)Y-Coord (ft)
CORKSCREW WTP - ASRL-5855425771775262

Start Test Date:01-JUN-1996 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):
Discharge Rate (gal/min):415Horizontal K (ft/day):
Hours Pumped:120Vertical K (ft/day):
Tested Interval Min. (ft BLS):328Storativity:
Tested Interval Max. (ft BLS):397Leakance (1/day):
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:SECOND MULTIWELL TEST OF ASR-1 FOLLOWED BACKPLUGGING OF MW-A TO INJECTION ZONE.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
LM-3982
426226
775260
COOPER-JACOB APPROXIMATION
400
1900
.00017
LM-3982
426226
775260
THEIS
400
1760
.00023
L-5858
425408
775264
COOPER-JACOB APPROXIMATION
400
3410
.000049
L-5858
425408
775264
THEIS
400
3180
.000057



SitePumped WellX-Coord(ft)Y-Coord (ft)
CORKSCREW WTP - ASRL-5855425771775262

Start Test Date:15-MAR-1999 0000Aquifer:MID-HAWTHORN AQUIFER
Test Type:APTTransmissivity (ft2/day):4295
Discharge Rate (gal/min):390Horizontal K (ft/day):62
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):328Storativity:.00004
Tested Interval Max. (ft BLS):397Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):44.8
SourceReferenceCitation Id
CONSULTANT WATER RESOURCE SOLUTIONS INC., SEPTEMBER 1999, CORKSCREW ASR EXPANSION PROJECT WELL COMPLETION REPORT
Comments:APT #4 -- ANALYSIS METHOD: HANTUSH JACOB (1955) TWO DIFFERENT MONITOR WELLS ANALYZED - LM-3982 (EAST SIDE)AND L-5858 ( WEST SIDE)--SEE SITE MAP. SEE ANALYSIS INFO FOR EAST SIDE MW VALUES. THESE RESULTS SUPPORT FINDINGS FROM PILOT ASR (APT #1, #2, #3) AND INDICATE THAT STORAGE ZONE TRANSMISSIVITY DECREASES APPROX. 50% OVER A WEST-TO-EAST DISTANCE.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
LM-3982
426226
775260
HANTUSH-JACOB (1955)
400
1658
.00028
.00032

Page generated at: 04-OCT-2025 11:46 EDT