DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CORKSCREW WTP - ASRL-5861424869776580

Start Test Date:25-JUN-1999 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):4020
Discharge Rate (gal/min):153-450Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):310Storativity:
Tested Interval Max. (ft BLS):368Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:TRANSMISSIVITY CALCULATED USING MODIFIED WALTON METHOD.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5861
424869
776580
OTHER
4020

Page generated at: 04-OCT-2025 03:55 EDT