DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CORKSCREW WTP - ASRL-5862423793779211

Start Test Date:20-JUL-1999 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):13400
Discharge Rate (gal/min):163-380Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):253Storativity:
Tested Interval Max. (ft BLS):291Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
 
Comments:TRANSMISSIVITY CALCULATED USING MODIFIED WALTON METHOD. SECOND STEP TEST OF ASR-5 WAS POST-ACIDIZATION OF THE WELL.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5862
423793
779211
OTHER
13400

Page generated at: 04-OCT-2025 03:59 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?