DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
WINKLER AVE - ASRL-5871368224825701

Start Test Date:23-OCT-1999 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):26050
Discharge Rate (gal/min):1400Horizontal K (ft/day):
Hours Pumped:27Vertical K (ft/day):
Tested Interval Min. (ft BLS):455Storativity:
Tested Interval Max. (ft BLS):553Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:RECOMMENDED PARAMETER FOR T VALUE IS AVERAGE OF C-J (NON-RECOVERY) METHOD OF ANALYSIS COOPER JACOB RECOVERY NOT AVERAGED IN PUMPING RATE FOR MULTIWELL TEST WAS 1540 FOR FIRST 6.5 HOURS, THEN CHANGED TO 1400. NO ATTEMPT WAS MADE TO ANALYZE MULTIWELL TEST DATA FOR STORAGE COEFFICIENT OR LEAKANCE. STORAGE ZONE IS LOCATED IN THE LOWER HAWTHORN PRODUCING ZONE OF THE UPPER FLORIDAN AQUIFER.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5871
368224
825701
COOPER-JACOB APPROXIMATION
0
3302
L-5871
368224
825701
RECOVERY
0
3396
L-5872
368224
825701
COOPER-JACOB APPROXIMATION
220
3663
L-5872
368224
825701
RECOVERY
220
387.7



SitePumped WellX-Coord(ft)Y-Coord (ft)
WINKLER AVE - ASRL-5871368224825701

Start Test Date:16-JUN-1999 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):29100
Discharge Rate (gal/min):479Horizontal K (ft/day):244.54
Hours Pumped:1Vertical K (ft/day):
Tested Interval Min. (ft BLS):455Storativity:
Tested Interval Max. (ft BLS):574Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY RON REESE. USGS, USGS WRI 02-4036
Comments:METHOD OF ANALYSIS COOPER JACOB RECOVERY

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5871
368224
825701
RECOVERY
3890



SitePumped WellX-Coord(ft)Y-Coord (ft)
WINKLER AVE - ASRL-5871368224825701

Start Test Date:17-JUN-1999 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):26600
Discharge Rate (gal/min):483Horizontal K (ft/day):221.67
Hours Pumped:.25Vertical K (ft/day):
Tested Interval Min. (ft BLS):455Storativity:
Tested Interval Max. (ft BLS):575Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:METHOD OF ANALYSIS COOPER JACOB RECOVERY

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L-5871
368224
825701
RECOVERY
3556

Page generated at: 01-JUL-2024 06:59 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?