DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-PW1
672741
826548
Start Test Date:
08-JAN-1997 0800
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
1375
Discharge Rate (gal/min):
245
Horizontal K (ft/day):
Hours Pumped:
73.25
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1400
Storativity:
.00012
Tested Interval Max. (ft BLS):
1810
Leakance (1/day):
.000071
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
TECH PUB WS-3, 05-2001
10
Comments:
THE MOENCH ANALYTICAL MODEL WAS USED TO ANALYZE DATA W-17093 = L2-TW
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
L2-TW
672742
826629
OTHER
262
1357
.00012
Page generated at: 04-OCT-2025 11:44 EDT