DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-PW1672741826548

Start Test Date:08-JAN-1997 0800Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):1375
Discharge Rate (gal/min):245Horizontal K (ft/day):
Hours Pumped:73.25Vertical K (ft/day):
Tested Interval Min. (ft BLS):1400Storativity:.00012
Tested Interval Max. (ft BLS):1810Leakance (1/day):.000071
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD TECH PUB WS-3, 05-200110
Comments:THE MOENCH ANALYTICAL MODEL WAS USED TO ANALYZE DATA W-17093 = L2-TW

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
L2-TW
672742
826629
OTHER
262
1357
.00012

Page generated at: 04-OCT-2025 11:44 EDT