DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-TW672742826629

Start Test Date:04-FEB-1994 0000Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):35Horizontal K (ft/day):
Hours Pumped:3Vertical K (ft/day):
Tested Interval Min. (ft BLS):1890Storativity:
Tested Interval Max. (ft BLS):1910Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-310
Comments:SPECIFIC CAPACITY = 0.43 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-TW672742826629

Start Test Date:07-FEB-1994 0000Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):4Horizontal K (ft/day):
Hours Pumped:5Vertical K (ft/day):
Tested Interval Min. (ft BLS):1266Storativity:
Tested Interval Max. (ft BLS):1286Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-310
Comments:SPECIFIC CAPACITY = 0.04 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-TW672742826629

Start Test Date:08-FEB-1994 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):35Horizontal K (ft/day):
Hours Pumped:5Vertical K (ft/day):
Tested Interval Min. (ft BLS):1652Storativity:
Tested Interval Max. (ft BLS):1704Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-310
Comments:SPECIFIC CAPACITY = 0.6 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-TW672742826629

Start Test Date:09-FEB-1994 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):35Horizontal K (ft/day):
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):1442Storativity:
Tested Interval Max. (ft BLS):1492Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-310
Comments:SPECIFIC CAPACITY = 0.4 GPM/FT

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
L2-TWL2-TW672742826629

Start Test Date:01-FEB-1994 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:SPECIFIC CAPACITYTransmissivity (ft2/day):4065
Discharge Rate (gal/min):75Horizontal K (ft/day):
Hours Pumped:2.25Vertical K (ft/day):
Tested Interval Min. (ft BLS):2075Storativity:
Tested Interval Max. (ft BLS):2124Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-310
Comments:TRANSMISSIVITY ESTIMATED FROM SPECIFIC CAPACITY

View Water Quality Results for the Above Test



Page generated at: 04-OCT-2025 06:37 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?