DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-TW
672742
826629
Start Test Date:
04-FEB-1994 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
35
Horizontal K (ft/day):
Hours Pumped:
3
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1890
Storativity:
Tested Interval Max. (ft BLS):
1910
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-3
10
Comments:
SPECIFIC CAPACITY = 0.43 GPM/FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-TW
672742
826629
Start Test Date:
07-FEB-1994 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
4
Horizontal K (ft/day):
Hours Pumped:
5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1266
Storativity:
Tested Interval Max. (ft BLS):
1286
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-3
10
Comments:
SPECIFIC CAPACITY = 0.04 GPM/FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-TW
672742
826629
Start Test Date:
08-FEB-1994 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
35
Horizontal K (ft/day):
Hours Pumped:
5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1652
Storativity:
Tested Interval Max. (ft BLS):
1704
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-3
10
Comments:
SPECIFIC CAPACITY = 0.6 GPM/FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-TW
672742
826629
Start Test Date:
09-FEB-1994 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
35
Horizontal K (ft/day):
Hours Pumped:
2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1442
Storativity:
Tested Interval Max. (ft BLS):
1492
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-3
10
Comments:
SPECIFIC CAPACITY = 0.4 GPM/FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L2-TW
L2-TW
672742
826629
Start Test Date:
01-FEB-1994 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
SPECIFIC CAPACITY
Transmissivity (ft2/day):
4065
Discharge Rate (gal/min):
75
Horizontal K (ft/day):
Hours Pumped:
2.25
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2075
Storativity:
Tested Interval Max. (ft BLS):
2124
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., May 2001, HYDROGEOLOGIC INVESTIGATION OF FLORIDAN AQUIFER SYSTEM AT L-2 CANAL SITE HENDRY COUNTY, FLORIDA Technical Publication WS-3
10
Comments:
TRANSMISSIVITY ESTIMATED FROM SPECIFIC CAPACITY
View Water Quality Results for the Above Test