DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
AT OBSERVATION WELL LAB-TW, STATION LAB-PW1 IN LABELLE
LAB-TW
502275
879739
Start Test Date:
11-MAR-1997 0000
Aquifer:
INTERMEDIATE AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
55
Horizontal K (ft/day):
Hours Pumped:
1.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
490
Storativity:
Tested Interval Max. (ft BLS):
540
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
BENNETT, M. W. 2003. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM. LABELLE, HENDRY COUNTY, FLORIDA. SFWMD TP WS-15.
12
Comments:
SPECIFIC CAPACITY = 0.6 GPM/FT, INDICATING POOR PRODUCTION SUSTAINED DRAWDOWN = 91.5 FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
AT OBSERVATION WELL LAB-TW, STATION LAB-PW1 IN LABELLE
LAB-TW
502275
879739
Start Test Date:
31-MAR-1997 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
Hours Pumped:
2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
670
Storativity:
Tested Interval Max. (ft BLS):
920
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
BENNETT, M. W. 2003. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM. LABELLE, HENDRY COUNTY, FLORIDA. SFWMD TP WS-15.
12
Comments:
SPECIFIC CAPACITY = 77 GPM/FT, INDICATING MODERATE PRODUCTIVITY DRAWDOWN = 12.1 FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
AT OBSERVATION WELL LAB-TW, STATION LAB-PW1 IN LABELLE
LAB-TW
502275
879739
Start Test Date:
02-MAY-1997 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
85
Horizontal K (ft/day):
Hours Pumped:
2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1145
Storativity:
Tested Interval Max. (ft BLS):
1270
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
BENNETT, M. W. 2003. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM. LABELLE, HENDRY COUNTY, FLORIDA. SFWMD TP WS-15.
12
Comments:
SPECIFIC CAPACITY = 1 GPM/FT, INDICATES LOW PRODUCTIVITY DRAWDOWN = 99.2 FT
View Water Quality Results for the Above Test
Page generated at: 04-OCT-2025 10:07 EDT