DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
LEIGHTON FARMSLF8918795381018915

Start Test Date:25-OCT-1956 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):7553
Discharge Rate (gal/min):725Horizontal K (ft/day):
Hours Pumped:27Vertical K (ft/day):
Tested Interval Min. (ft BLS):Storativity:.0034
Tested Interval Max. (ft BLS):75Leakance (1/day):.0025
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECH PUB 96-02 (WRE#337)333
Comments:

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
LF892
879571
1018776
COOPER-JACOB APPROXIMATION
190
9.8
4011
.00023
.0009
LF894
880738
1019415
COOPER-JACOB APPROXIMATION
1300
.4
11096
.0065
.0041

Page generated at: 04-OCT-2025 06:39 EDT