DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-DIW443006830654

Start Test Date:03-FEB-2008 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):17.6
Discharge Rate (gal/min):32Horizontal K (ft/day):.59
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1940Storativity:
Tested Interval Max. (ft BLS):1970Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-DIW443006830654

Start Test Date:04-FEB-2008 0002Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):9.85
Discharge Rate (gal/min):21Horizontal K (ft/day):.16
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1855Storativity:
Tested Interval Max. (ft BLS):1915Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-DIW443006830654

Start Test Date:05-FEB-2008 0003Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):26.8
Discharge Rate (gal/min):36Horizontal K (ft/day):.27
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1990Storativity:
Tested Interval Max. (ft BLS):2088Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-DIW443006830654

Start Test Date:05-FEB-2008 0004Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):13527
Discharge Rate (gal/min):115Horizontal K (ft/day):135.27
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):2130Storativity:
Tested Interval Max. (ft BLS):2230Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES

Page generated at: 04-OCT-2025 11:50 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?