DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-LZMWB443064830685

Start Test Date:18-AUG-2008 0630Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):48.3
Discharge Rate (gal/min):82Horizontal K (ft/day):.41
Hours Pumped:3.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1788Storativity:
Tested Interval Max. (ft BLS):1907Leakance (1/day):
No. Monitored Wells:16Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-LZMWB443064830685

Start Test Date:19-AUG-2008 1900Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):9.55
Discharge Rate (gal/min):22Horizontal K (ft/day):.16
Hours Pumped:3.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1693Storativity:
Tested Interval Max. (ft BLS):1753Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-LZMWB443064830685

Start Test Date:20-AUG-2008 1600Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2.8
Discharge Rate (gal/min):7Horizontal K (ft/day):
Hours Pumped:3.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1673Storativity:
Tested Interval Max. (ft BLS):1613Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES



SitePumped WellX-Coord(ft)Y-Coord (ft)
LEHIGH ACRES DEEP INJECTION FACILITYLHA-LZMWB443064830685

Start Test Date:21-AUG-2008 1000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):8.7
Discharge Rate (gal/min):23Horizontal K (ft/day):
Hours Pumped:3.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1583Storativity:
Tested Interval Max. (ft BLS):1523Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PBS&J, JUNE 2008, ENGINEERING REPORT FOR THE CONSTRUCTION AND TESTING OF LEHIGH ACRES DEEP INJECTION WELL
Comments:TRANSMISSIVITY VALUE IS AVERAGE OF DRAWDOWN AND RECOVERY VALUES

Page generated at: 28-SEP-2024 21:31 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?