DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA BAY
LM-1718
391825
734438
Start Test Date:
13-AUG-1981 1201
Aquifer:
MID-HAWTHORN AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
11096
Discharge Rate (gal/min):
400
Horizontal K (ft/day):
Hours Pumped:
28
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
235
Storativity:
.000041
Tested Interval Max. (ft BLS):
255
Leakance (1/day):
.00001
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
Dabbs, Clyde, 2003, Hydrostratigraphy Review Report. BEM Systems, Inc., Missimer & Associates, 1981, Groundwater resources of the Bonita Bay Development
Comments:
THE DATE OF THE APT TEST IS THE YEAR OF THE REPORT. HANT-JAC/JACOB METHOD AQUIFER REPORTED AS HAWTHORN ZONE I
Page generated at: 04-OCT-2025 05:26 EDT