DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BONITA BAYLM-1718391825734438

Start Test Date:13-AUG-1981 1201Aquifer:MID-HAWTHORN AQUIFER
Test Type:APTTransmissivity (ft2/day):11096
Discharge Rate (gal/min):400Horizontal K (ft/day):
Hours Pumped:28Vertical K (ft/day):
Tested Interval Min. (ft BLS):235Storativity:.000041
Tested Interval Max. (ft BLS):255Leakance (1/day):.00001
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT Dabbs, Clyde, 2003, Hydrostratigraphy Review Report. BEM Systems, Inc., Missimer & Associates, 1981, Groundwater resources of the Bonita Bay Development
Comments:THE DATE OF THE APT TEST IS THE YEAR OF THE REPORT. HANT-JAC/JACOB METHOD AQUIFER REPORTED AS HAWTHORN ZONE I