DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
LAKE REGION RO TREATMENT PLANTLRRO-PW6759106874810

Start Test Date:08-MAR-2011 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):14237
Discharge Rate (gal/min):1710Horizontal K (ft/day):
Hours Pumped:144Vertical K (ft/day):
Tested Interval Min. (ft BLS):1150Storativity:.00026
Tested Interval Max. (ft BLS):1450Leakance (1/day):.002
No. Monitored Wells:7Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT JLA GEOSCIENCES, APRIL 2011. GLADES UTILITY AUTHORITY, UPPER FLORIDAN AQUIFER AQUIFER PERFORMANCE TESTING RESULTS.
Comments:THIS WAS A COMPLICATED TEST, INCORPORATING MULTIPLE PRODUCTION WELLS AT STAGGERED INTERVALS IN ORDER TO CONDUCT THE TEST IN AN OPERATIONAL WELLFIELD. IT IS RECOMMENDED THAT THE READER CONSULT THE ATTACHED APT REPORT FOR ADDITIONAL DETAILS.