DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LAKE REGION RO TREATMENT PLANT
LRRO-PW9
762657
869743
Start Test Date:
19-NOV-2014 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
Discharge Rate (gal/min):
965
Horizontal K (ft/day):
Hours Pumped:
1
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1052
Storativity:
Tested Interval Max. (ft BLS):
1363
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
33.2
Source
Reference
Citation Id
CONSULTANT
JLA GEOSCIENCES, AUG. 2015. WELL CONSTRUCTION AND TESTING REPORT FOR UPER FLORIDAN PRODUCTION WELLS PW-9 & PW-10; PALM BEACH COUNTY WATER UTILITIES DEPARTMENT WATER TREATMENT PLANT NO 11, BELLE GLADE, FL
Comments:
SPECIFIC CAPACITY (SC) REPORTED FOR THE DESIGN RATE, SPECIFIC CONDUCTANCE = 5,520 [US/CM] UNUSUAL DIFFERENCE IN SC & SALINITY BETWEEN THIS WELL AND NEIGHBORING LRRO-PW10.
Page generated at: 04-OCT-2025 08:38 EDT