DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:14-JAN-2021 1202Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):20.10Horizontal K (ft/day):
Hours Pumped:2.37Vertical K (ft/day):
Tested Interval Min. (ft BLS):700Storativity:
Tested Interval Max. (ft BLS):730Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):3.18
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:25-JAN-2021 1600Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):24.00Horizontal K (ft/day):
Hours Pumped:.3Vertical K (ft/day):
Tested Interval Min. (ft BLS):730Storativity:
Tested Interval Max. (ft BLS):760Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):4.2
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:26-JAN-2021 1514Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):21.40Horizontal K (ft/day):
Hours Pumped:1.57Vertical K (ft/day):
Tested Interval Min. (ft BLS):760Storativity:
Tested Interval Max. (ft BLS):790Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.1
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:27-JAN-2021 1409Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):1.50Horizontal K (ft/day):
Hours Pumped:1.43Vertical K (ft/day):
Tested Interval Min. (ft BLS):790Storativity:
Tested Interval Max. (ft BLS):820Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.21
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:28-JAN-2021 1312Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):1.00Horizontal K (ft/day):
Hours Pumped:1.42Vertical K (ft/day):
Tested Interval Min. (ft BLS):820Storativity:
Tested Interval Max. (ft BLS):850Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.14
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:01-FEB-2021 1720Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):0.80Horizontal K (ft/day):
Hours Pumped:.9Vertical K (ft/day):
Tested Interval Min. (ft BLS):850Storativity:
Tested Interval Max. (ft BLS):885Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.17
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:02-FEB-2021 1310Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):1.80Horizontal K (ft/day):
Hours Pumped:.65Vertical K (ft/day):
Tested Interval Min. (ft BLS):880Storativity:
Tested Interval Max. (ft BLS):910Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.1
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:03-FEB-2021 1240Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):20.10Horizontal K (ft/day):
Hours Pumped:2.17Vertical K (ft/day):
Tested Interval Min. (ft BLS):910Storativity:
Tested Interval Max. (ft BLS):940Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.24
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:05-FEB-2021 1013Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):24.20Horizontal K (ft/day):
Hours Pumped:1.23Vertical K (ft/day):
Tested Interval Min. (ft BLS):940Storativity:
Tested Interval Max. (ft BLS):970Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.25
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:09-FEB-2021 1046Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.30Horizontal K (ft/day):
Hours Pumped:1.17Vertical K (ft/day):
Tested Interval Min. (ft BLS):970Storativity:
Tested Interval Max. (ft BLS):1000Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.45
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:10-FEB-2021 1300Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):27.80Horizontal K (ft/day):
Hours Pumped:1.77Vertical K (ft/day):
Tested Interval Min. (ft BLS):1000Storativity:
Tested Interval Max. (ft BLS):1030Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.7
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:11-FEB-2021 1349Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):31.10Horizontal K (ft/day):
Hours Pumped:1.18Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:
Tested Interval Max. (ft BLS):1060Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.2
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:15-FEB-2021 1127Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):30.00Horizontal K (ft/day):
Hours Pumped:1.27Vertical K (ft/day):
Tested Interval Min. (ft BLS):1060Storativity:
Tested Interval Max. (ft BLS):1090Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.4
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:17-FEB-2021 0924Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):25.80Horizontal K (ft/day):
Hours Pumped:1.03Vertical K (ft/day):
Tested Interval Min. (ft BLS):1090Storativity:
Tested Interval Max. (ft BLS):1120Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.8
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:18-FEB-2021 0946Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.80Horizontal K (ft/day):
Hours Pumped:1.3Vertical K (ft/day):
Tested Interval Min. (ft BLS):1120Storativity:
Tested Interval Max. (ft BLS):1150Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.6
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:19-FEB-2021 1225Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):26.50Horizontal K (ft/day):
Hours Pumped:.82Vertical K (ft/day):
Tested Interval Min. (ft BLS):1150Storativity:
Tested Interval Max. (ft BLS):1180Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.6
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:23-FEB-2021 1244Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):24.40Horizontal K (ft/day):
Hours Pumped:1.72Vertical K (ft/day):
Tested Interval Min. (ft BLS):1180Storativity:
Tested Interval Max. (ft BLS):1210Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.7
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:10-MAR-2021 1521Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):26.50Horizontal K (ft/day):
Hours Pumped:.82Vertical K (ft/day):
Tested Interval Min. (ft BLS):1210Storativity:
Tested Interval Max. (ft BLS):1240Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.5
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:11-MAR-2021 1145Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):29.40Horizontal K (ft/day):
Hours Pumped:.85Vertical K (ft/day):
Tested Interval Min. (ft BLS):1240Storativity:
Tested Interval Max. (ft BLS):1270Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.2
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:12-MAR-2021 0840Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):29.10Horizontal K (ft/day):
Hours Pumped:2.23Vertical K (ft/day):
Tested Interval Min. (ft BLS):1270Storativity:
Tested Interval Max. (ft BLS):1300Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.2
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:16-MAR-2021 1557Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):30.10Horizontal K (ft/day):
Hours Pumped:.92Vertical K (ft/day):
Tested Interval Min. (ft BLS):1300Storativity:
Tested Interval Max. (ft BLS):1330Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):74.12
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:18-MAR-2021 1035Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.70Horizontal K (ft/day):
Hours Pumped:2.03Vertical K (ft/day):
Tested Interval Min. (ft BLS):1330Storativity:
Tested Interval Max. (ft BLS):1360Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):4.9
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:07-APR-2021 1132Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):26.30Horizontal K (ft/day):
Hours Pumped:2.22Vertical K (ft/day):
Tested Interval Min. (ft BLS):1360Storativity:
Tested Interval Max. (ft BLS):1390Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):50.99
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:08-APR-2021 1308Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.10Horizontal K (ft/day):
Hours Pumped:2.63Vertical K (ft/day):
Tested Interval Min. (ft BLS):1390Storativity:
Tested Interval Max. (ft BLS):1420Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):12.4
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:12-APR-2021 1459Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.10Horizontal K (ft/day):
Hours Pumped:1.58Vertical K (ft/day):
Tested Interval Min. (ft BLS):1420Storativity:
Tested Interval Max. (ft BLS):1450Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):42.9
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:14-APR-2021 0835Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.60Horizontal K (ft/day):
Hours Pumped:1.17Vertical K (ft/day):
Tested Interval Min. (ft BLS):1450Storativity:
Tested Interval Max. (ft BLS):1480Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.74
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:15-APR-2021 0838Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.40Horizontal K (ft/day):
Hours Pumped:1.12Vertical K (ft/day):
Tested Interval Min. (ft BLS):1480Storativity:
Tested Interval Max. (ft BLS):1510Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.45
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:16-APR-2021 0940Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):26.50Horizontal K (ft/day):
Hours Pumped:1.13Vertical K (ft/day):
Tested Interval Min. (ft BLS):1510Storativity:
Tested Interval Max. (ft BLS):1540Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):15.8
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:20-APR-2021 1206Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.10Horizontal K (ft/day):
Hours Pumped:1.07Vertical K (ft/day):
Tested Interval Min. (ft BLS):1540Storativity:
Tested Interval Max. (ft BLS):1570Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):64.1
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:23-APR-2021 0907Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.00Horizontal K (ft/day):
Hours Pumped:1.55Vertical K (ft/day):
Tested Interval Min. (ft BLS):1570Storativity:
Tested Interval Max. (ft BLS):1600Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):123.7
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:28-APR-2021 0754Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):27.60Horizontal K (ft/day):
Hours Pumped:1.63Vertical K (ft/day):
Tested Interval Min. (ft BLS):1600Storativity:
Tested Interval Max. (ft BLS):1630Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):264.91
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:29-APR-2021 0825Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):28.60Horizontal K (ft/day):
Hours Pumped:1.75Vertical K (ft/day):
Tested Interval Min. (ft BLS):1630Storativity:
Tested Interval Max. (ft BLS):1660Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.02
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:30-APR-2021 0759Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.70Horizontal K (ft/day):
Hours Pumped:1.88Vertical K (ft/day):
Tested Interval Min. (ft BLS):1660Storativity:
Tested Interval Max. (ft BLS):1690Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.09
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:04-MAY-2021 0741Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):10.90Horizontal K (ft/day):
Hours Pumped:2.22Vertical K (ft/day):
Tested Interval Min. (ft BLS):1690Storativity:
Tested Interval Max. (ft BLS):1720Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.16
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:05-MAY-2021 0755Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.40Horizontal K (ft/day):
Hours Pumped:2.47Vertical K (ft/day):
Tested Interval Min. (ft BLS):1720Storativity:
Tested Interval Max. (ft BLS):1750Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.09
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:06-MAY-2021 0738Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.00Horizontal K (ft/day):
Hours Pumped:.07Vertical K (ft/day):
Tested Interval Min. (ft BLS):1750Storativity:
Tested Interval Max. (ft BLS):1780Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.07
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:07-MAY-2021 0745Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.00Horizontal K (ft/day):
Hours Pumped:.08Vertical K (ft/day):
Tested Interval Min. (ft BLS):1780Storativity:
Tested Interval Max. (ft BLS):1810Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.07
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:11-MAY-2021 0741Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.00Horizontal K (ft/day):
Hours Pumped:.13Vertical K (ft/day):
Tested Interval Min. (ft BLS):1810Storativity:
Tested Interval Max. (ft BLS):1840Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.07
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:12-MAY-2021 0803Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.00Horizontal K (ft/day):
Hours Pumped:.05Vertical K (ft/day):
Tested Interval Min. (ft BLS):1840Storativity:
Tested Interval Max. (ft BLS):1870Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.07
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:13-MAY-2021 1056Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):9.50Horizontal K (ft/day):
Hours Pumped:1.75Vertical K (ft/day):
Tested Interval Min. (ft BLS):1870Storativity:
Tested Interval Max. (ft BLS):1900Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):.29
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:25-MAY-2021 0809Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):25.70Horizontal K (ft/day):
Hours Pumped:1.88Vertical K (ft/day):
Tested Interval Min. (ft BLS):1900Storativity:
Tested Interval Max. (ft BLS):1930Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):1.79
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:26-MAY-2021 1130Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):26.00Horizontal K (ft/day):
Hours Pumped:1.6Vertical K (ft/day):
Tested Interval Min. (ft BLS):1930Storativity:
Tested Interval Max. (ft BLS):1960Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):2.53
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
TAYLOR CREEK FLORIDA AQUIFER MONITORING SITEM01L63N7256411056269

Start Test Date:01-JUN-2021 1057Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.10Horizontal K (ft/day):
Hours Pumped:1.65Vertical K (ft/day):
Tested Interval Min. (ft BLS):1960Storativity:
Tested Interval Max. (ft BLS):2000Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):4.18
SourceReferenceCitation Id
CONSULTANT STANTEC, 2021 CONTINUOUS CORING PROGRAM390
Comments:

View Water Quality Results for the Above Test



Page generated at: 04-OCT-2025 08:22 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?