DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANT
MC-5003
433672
695082
Start Test Date:
03-FEB-1995 1010
Aquifer:
MID-HAWTHORN AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
2580
Discharge Rate (gal/min):
540
Horizontal K (ft/day):
22
Hours Pumped:
70
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
398
Storativity:
.00087
Tested Interval Max. (ft BLS):
514
Leakance (1/day):
.00015
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, OCTOBER 1995. COLLIER COUNTY UTILITIES BRACKISH WATER WELLFIELD STUDY. PROJECT FH4-26.
Comments:
PARAMETER VALUES DETERMINED FROM AVERAGE OF COOPER '63 AND JACOB '50 VALUES. LEAKANCE FROM COOPER ONLY. * IN ANALYSIS INFO, METHOD IS LISTED AS OTHER IS COOPER 1963 AND THAT LISTED AS UNKNOWN IS JACOB 1950.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
MC-5000
433701
694941
OTHER
565
2580
.00087
.00015
MC-5000
433701
694941
UNKNOWN
565
2955
.000098
Page generated at: 28-SEP-2024 20:23 EDT