DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
MC-5055
431530
666867
Start Test Date:
30-SEP-2000 2300
Aquifer:
MID-HAWTHORN AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
12834
Discharge Rate (gal/min):
775
Horizontal K (ft/day):
Hours Pumped:
77
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
295
Storativity:
.00014
Tested Interval Max. (ft BLS):
400
Leakance (1/day):
.0003
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MDM/MISSIMER INTERNATIONAL INC. OCTOBER, 2000. COLLIER COUNTY PUBLIC WORKS SOUTHERN REVERSE OSMOSIS WELLFIELD STUDY, COLLIER COUNTY, FL. PROJECT No: FH8-812/9086-28655-DN.FWF
Comments:
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
MC-5056
441453
668622
JACOB STRAIGHT-LINE (1952)
735
13770
.00012
MC-5056
441453
668622
OTHER
735
14037
.00015
.00017
MC-5056
441453
668622
RECOVERY
735
10963
.00019
MC-5069
431099
673153
JACOB STRAIGHT-LINE (1952)
405
6016
.000057
MC-5069
431099
673153
OTHER
405
5829
.000083
.000024
MC-5069
431099
673153
RECOVERY
405
5829
.00011
Page generated at: 01-JUL-2024 00:35 EDT