DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
25-AUG-1977 0812
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
8.54
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.39
Hours Pumped:
.7
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2737
Storativity:
Tested Interval Max. (ft BLS):
2759
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF THE TEST-INJECTION WELL, I-5, FOR MDWASA, DECEMBER 1977
Comments:
PACKER TEST 1 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
25-AUG-1977 1225
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
12.5
Discharge Rate (gal/min):
4
Horizontal K (ft/day):
.42
Hours Pumped:
3.2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2697
Storativity:
Tested Interval Max. (ft BLS):
2727
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF THE TEST-INJECTION WELL, I-5, FOR MDWASA, DECEMBER 1977
Comments:
PACKER TEST 2 OF 10 PUMP ADJUSTED TO 7.9 GPM AT TIME 1310 AND TO 23 GPM AT TIME 1424 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
25-AUG-1977 2317
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
19
Discharge Rate (gal/min):
24.5
Horizontal K (ft/day):
.63
Hours Pumped:
3.31
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2367
Storativity:
Tested Interval Max. (ft BLS):
2397
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDWASA, DECEMBER 1977
Comments:
PACKER TEST 3 OF 10 (PARTS 1 & 2)--PUMPED WAS STOPPED AT 42 MIN INTO PUMPING AT RATE OF 12.8 GPM (PART 1); BEGAN PUMPING AGAIN AT RATE OF 24.5 GPM FOR 2.6 HOURS--TRANSMISSIVITY IS AVERAGE OF THE TWO TESTS LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
26-AUG-1977 0747
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
47.4
Discharge Rate (gal/min):
61
Horizontal K (ft/day):
.13
Hours Pumped:
1.55
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2407
Storativity:
Tested Interval Max. (ft BLS):
2759
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 4 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
26-AUG-1977 1558
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
24
Discharge Rate (gal/min):
42.5
Horizontal K (ft/day):
.8
Hours Pumped:
1.28
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1968
Storativity:
Tested Interval Max. (ft BLS):
1998
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 5 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
26-AUG-1977 1814
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
88.5
Discharge Rate (gal/min):
61
Horizontal K (ft/day):
.12
Hours Pumped:
.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2008
Storativity:
Tested Interval Max. (ft BLS):
2759
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 6 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
27-AUG-1977 1150
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
19.4
Discharge Rate (gal/min):
55
Horizontal K (ft/day):
.65
Hours Pumped:
1.88
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2543
Storativity:
Tested Interval Max. (ft BLS):
2573
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 7 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
27-AUG-1977 1628
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
44.2
Discharge Rate (gal/min):
33
Horizontal K (ft/day):
.25
Hours Pumped:
1.78
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2583
Storativity:
Tested Interval Max. (ft BLS):
2759
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 8 OF 10 PUMPING RATE WAS INCREASED TO 60 GPM AT TIME 1733 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
28-AUG-1977 0130
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
35.8
Discharge Rate (gal/min):
12
Horizontal K (ft/day):
.53
Hours Pumped:
2.8
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2692
Storativity:
Tested Interval Max. (ft BLS):
2759
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 9 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MIAMI DADE WATER AND SEWER AUTH. SO. DISTRICT REGIONAL WWTP
MDWSA_I5
876306
442462
Start Test Date:
28-AUG-1977 0554
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
13
Discharge Rate (gal/min):
20
Horizontal K (ft/day):
.43
Hours Pumped:
2.4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2652
Storativity:
Tested Interval Max. (ft BLS):
2682
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DRILLING AND TESTING OF TEST-INJECTION WELL, I-5, FOR MDSAWA, DECEMBER 1977
Comments:
PACKER TEST 10 OF 10 LEAKANCE WAS NOT DETERMINED DUE TO VERY SMALL DRAWDOWN IN BOULDER ZONE
Page generated at: 04-OCT-2025 08:14 EDT