SitePumped WellX-Coord(ft)Y-Coord (ft)
SFWMD FAS ALLAPATAH C-23 TEST SITEMF-418262931044362

Start Test Date:16-OCT-2006 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):255359
Discharge Rate (gal/min):2000Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):64
Tested Interval Min. (ft BLS):790Storativity:.0047
Tested Interval Max. (ft BLS):970Leakance (1/day):.49
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SUNDERLAND, R.SIMON. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM C-23 CANAL SITE MARTIN COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-24. SEPT. 2008217
Comments:HANTUSH-JACOB SOLUTION.



SitePumped WellX-Coord(ft)Y-Coord (ft)
SFWMD FAS ALLAPATAH C-23 TEST SITEMF-418262931044362

Start Test Date:13-DEC-2007 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):
Discharge Rate (gal/min):1300Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):1100Storativity:
Tested Interval Max. (ft BLS):1305Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SUNDERLAND, R.SIMON. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM C-23 CANAL SITE MARTIN COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-24. SEPT. 2008217
Comments:HANTUSH-JACOB YIELDED A T=1,107,000 ft2/d due to very low monitor well drawdown. The PW well drawdown was ~200 ft at the rate of 1,300 gpm, indicating much lower transmissivity. Variation is believed to be due to highly fractured nature of formation in the monitor well in comparison to the much less productive PW. These things limit the value of the monitor well data.