DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SFWMD FAS ALLAPATAH C-23 TEST SITE
MF-41
826293
1044362
Start Test Date:
16-OCT-2006 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
255359
Discharge Rate (gal/min):
2000
Horizontal K (ft/day):
Hours Pumped:
24
Vertical K (ft/day):
64
Tested Interval Min. (ft BLS):
790
Storativity:
.0047
Tested Interval Max. (ft BLS):
970
Leakance (1/day):
.49
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
SUNDERLAND, R.SIMON. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM C-23 CANAL SITE MARTIN COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-24. SEPT. 2008
217
Comments:
HANTUSH-JACOB SOLUTION.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SFWMD FAS ALLAPATAH C-23 TEST SITE
MF-41
826293
1044362
Start Test Date:
13-DEC-2007 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
Discharge Rate (gal/min):
1300
Horizontal K (ft/day):
Hours Pumped:
24
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1100
Storativity:
Tested Interval Max. (ft BLS):
1305
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
SUNDERLAND, R.SIMON. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM C-23 CANAL SITE MARTIN COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-24. SEPT. 2008
217
Comments:
HANTUSH-JACOB YIELDED A T=1,107,000 ft2/d due to very low monitor well drawdown. The PW well drawdown was ~200 ft at the rate of 1,300 gpm, indicating much lower transmissivity. Variation is believed to be due to highly fractured nature of formation in the monitor well in comparison to the much less productive PW. These things limit the value of the monitor well data.
Page generated at: 04-OCT-2025 06:38 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?