DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
MOBIL M1282MOBIL_PW9071381003865

Start Test Date:09-OCT-1989 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):2005
Discharge Rate (gal/min):136Horizontal K (ft/day):38
Hours Pumped:42.9Vertical K (ft/day):
Tested Interval Min. (ft BLS):60Storativity:.0002
Tested Interval Max. (ft BLS):85Leakance (1/day):
No. Monitored Wells:4Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECH PUB 96-02 (WRE #337)333
Comments:

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
1D_MOBIL
907214
1003915
NEUMAN-WITHERSPOON
75
2253
.00035
1I_MOBIL
907214
1003880
NEUMAN-WITHERSPOON
76
1685
.00015
2D_MOBIL
907289
1003915
NEUMAN-WITHERSPOON
151
2205
.0002
2I_MOBIL
907291
1003865
NEUMAN-WITHERSPOON
153
1993
.00018

Page generated at: 04-OCT-2025 07:02 EDT