SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:29-DEC-1995 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):10.8
Discharge Rate (gal/min):2Horizontal K (ft/day):.6
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1862Storativity:
Tested Interval Max. (ft BLS):1880Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:29-DEC-1995 0002Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):10.8
Discharge Rate (gal/min):3.3Horizontal K (ft/day):.6
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1862Storativity:
Tested Interval Max. (ft BLS):1880Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:29-DEC-1995 0003Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):10.8
Discharge Rate (gal/min):5.4Horizontal K (ft/day):.6
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1862Storativity:
Tested Interval Max. (ft BLS):1880Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:03-JAN-1996 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):43.4
Discharge Rate (gal/min):1Horizontal K (ft/day):1.97
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2116Storativity:
Tested Interval Max. (ft BLS):2138Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:03-JAN-1996 0002Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):43.4
Discharge Rate (gal/min):3.2Horizontal K (ft/day):1.97
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2116Storativity:
Tested Interval Max. (ft BLS):2138Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:03-JAN-1996 0003Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):37.9
Discharge Rate (gal/min):7Horizontal K (ft/day):1.72
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2116Storativity:
Tested Interval Max. (ft BLS):2138Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:03-JAN-1996 0004Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):35.2
Discharge Rate (gal/min):11Horizontal K (ft/day):1.6
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2116Storativity:
Tested Interval Max. (ft BLS):2138Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:07-JAN-1996 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):3.25
Discharge Rate (gal/min):2Horizontal K (ft/day):.14
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2236Storativity:
Tested Interval Max. (ft BLS):2259Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH COLLIER COUNTY WASTE WATER TREATMENT PLANTNCRWTP-IW2434195695522

Start Test Date:11-JAN-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2141
Discharge Rate (gal/min):108Horizontal K (ft/day):101.95
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2434Storativity:
Tested Interval Max. (ft BLS):2455Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, 08-1996, COMPLETION REPORT
Comments:T VALUE BASED ON SPECIFIC CAPACITY