DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
NORTH COLLIER WATER RECLAMATION FACILITY
NCWRF-IW1
398377
701833
Start Test Date:
12-FEB-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
2.82
Discharge Rate (gal/min):
74
Horizontal K (ft/day):
.02
Hours Pumped:
3.75
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1198
Storativity:
Tested Interval Max. (ft BLS):
1357
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
WRS, JANUARY 2004 (NORTH COLLIER WATER RECLAMATION FACILITY WELL COMPLETION REPORT FOR IW-1 AND DZMW VOLUME 1)
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
NORTH COLLIER WATER RECLAMATION FACILITY
NCWRF-IW1
398377
701833
Start Test Date:
26-FEB-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
11.3
Discharge Rate (gal/min):
67
Horizontal K (ft/day):
.23
Hours Pumped:
2.48
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1450
Storativity:
Tested Interval Max. (ft BLS):
1500
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
WRS, JANUARY 2004 (NORTH COLLIER WATER RECLAMATION FACILITY WELL COMPLETION REPORT FOR IW-1 AND DZMW VOLUME 1)
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
NORTH COLLIER WATER RECLAMATION FACILITY
NCWRF-IW1
398377
701833
Start Test Date:
03-MAR-2003 0000
Aquifer:
LOWER FLORIDAN AQUIFER (FZ2)
Test Type:
PACKER
Transmissivity (ft2/day):
17.9
Discharge Rate (gal/min):
67
Horizontal K (ft/day):
.36
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1875
Storativity:
Tested Interval Max. (ft BLS):
1925
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
WRS, JANUARY 2004 (NORTH COLLIER WATER RECLAMATION FACILITY WELL COMPLETION REPORT FOR IW-1 AND DZMW VOLUME 1)
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
NORTH COLLIER WATER RECLAMATION FACILITY
NCWRF-IW1
398377
701833
Start Test Date:
23-MAR-2003 0000
Aquifer:
LOWER FLORIDAN AQUIFER (FZ2)
Test Type:
PACKER
Transmissivity (ft2/day):
188.2
Discharge Rate (gal/min):
200
Horizontal K (ft/day):
.26
Hours Pumped:
4.58
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2539
Storativity:
Tested Interval Max. (ft BLS):
3250
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
WRS, JANUARY 2004 (NORTH COLLIER WATER RECLAMATION FACILITY WELL COMPLETION REPORT FOR IW-1 AND DZMW VOLUME 1)