Start Test Date: | 01-AUG-2005 0000 | Aquifer: | FLORIDAN AQUIFER SYSTEM |
Test Type: | APT | Transmissivity (ft2/day): | 14243 |
Discharge Rate (gal/min): | 1574 | Horizontal K (ft/day): | |
Hours Pumped: | 336 | Vertical K (ft/day): | |
Tested Interval Min. (ft BLS): | 261 | Storativity: | .0004 |
Tested Interval Max. (ft BLS): | 502 | Leakance (1/day): | .0034 |
No. Monitored Wells: | | Specific Capacity (gpm/ft): | |