DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FPL OKEECHOBEE CLEAN ENERGY CENTER
OCEC_FA-1
722488
1200374
Start Test Date:
04-APR-2017 1200
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
132400
Discharge Rate (gal/min):
2996
Horizontal K (ft/day):
390
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
372
Storativity:
.001
Tested Interval Max. (ft BLS):
800
Leakance (1/day):
.052
No. Monitored Wells:
3
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
JLA GEOSCIENCES, FPL OKEECHOBEE CLEAN ENERGY CENTER, AQUIFER PERFORMANCE TESTING REPORT, MAY 22,2017
276
Comments:
LEAKAANCE IS ASSUMED TO BE FROM BELOW (APPZ SOURCE), MW FA-3 COMPLETED 200' SHALLOWER THAN THE PRODUCTION WELL. T IS AVERAGE OF THREE MONITOR WELLS.
Page generated at: 04-OCT-2025 10:12 EDT