DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ORANGE COUNTY UTILITIES EASTERN WATER RECLAMATION FACILITY
OCUASRLF-1
589163
1521605
Start Test Date:
05-JAN-2009 0000
Aquifer:
LOWER FLORIDAN AQUIFER (FZ1)
Test Type:
APT
Transmissivity (ft2/day):
136000
Discharge Rate (gal/min):
2143
Horizontal K (ft/day):
Hours Pumped:
48
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1045
Storativity:
Tested Interval Max. (ft BLS):
1190
Leakance (1/day):
No. Monitored Wells:
3
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
BARNES & FERLAND, WELL CONSTRUCTION AND TESTING REPORT ORANGE COUNTY UTILITIES EASTERN WATER REC. FACILITY ASR TEST WELL AND MONITOR WELL CONSTRUCTION. MAY, 2009
Comments:
UNDERDAMPED AQUIFER RESPONSE LIMITED INTERPRETATION OF DATA. TRANSMISSIVITY WAS ESTIMATED USING THE JACOB DISTANCE-DRAWDOWN METHOD.