DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 138
OCU_SRWF
532962
1467830
Start Test Date:
24-JAN-1995 1545
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
412500
Discharge Rate (gal/min):
5150
Horizontal K (ft/day):
Hours Pumped:
89
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1100
Storativity:
.004
Tested Interval Max. (ft BLS):
1690
Leakance (1/day):
.003
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Data compiled in USGS WRIR 02-4036, data originally from, BOYLE ENGINEERING CORP
Comments:
TRANSMISSIVITY = AVERAGE OF 365K+460K NEUMAN-WITHERSPOON ANALYSIS YIELDED DISCRETIZED LEAKANCE FOR THE OVER & UNDERLYING CONFINING UNITS: MIDDLE-SEMI- CONFINING UNIT (.OO5 1/D) & LOWER CONFINING UNIT (.003 1/D). NOTE: PRIMARY PRODUCTION ABOVE 1,400 FT BLS, WHICH WAS THE ACTUAL COMPLETED DEPTH FOR THE SOUTHERN REGIONAL WELLFIELD.