DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
DRILLER: GRAY WELL AND PUMP CO., JAX, FL.
OKF-26
712616
1081413
Start Test Date:
01-JAN-1984 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
OTHER
Transmissivity (ft2/day):
867.2
Discharge Rate (gal/min):
400
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
625
Storativity:
Tested Interval Max. (ft BLS):
825
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
SHAW, J.E. AND S.M. TROST. 1984. HYDROGEOLOGY OF THE KISSIMMEE PLANNING AREA, SFWMD TP 84-1.
149
Comments:
TRANSMISSIVITY ESTIMATED FROM CORRECTED SPECIFIC CAPACITY = 5.03 GPM/FT DRAWDOWN CORRECTED FOR FRICTION = 79.59 FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
DRILLER: GRAY WELL AND PUMP CO., JAX, FL.
OKF-26
712616
1081413
Start Test Date:
25-DEC-1992 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
SPECIFIC CAPACITY
Transmissivity (ft2/day):
7445
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
625
Storativity:
Tested Interval Max. (ft BLS):
825
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Data compiled in SFWMD TP 92-03, originally from, TROST, S.M. 1985. FLORIDAN AQUIFER RESOURCE ASSESSMENT, UPPER EAST COAST PLANNING AREA. SFWMD UNPUBLISHED TECHNICAL PUBLICATION.
335
Comments:
TRANSMISSIVITY ESTIMATED FROM SPECIFIC CAPACITY FIT TO REGRESSION CURVE
Page generated at: 04-OCT-2025 10:12 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?