DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
AT STATION W-16951OKF-827482511079459

Start Test Date:04-JAN-1994 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):4278
Discharge Rate (gal/min):3680Horizontal K (ft/day):3
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):742Storativity:.0014
Tested Interval Max. (ft BLS):942Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD J. HERR, UNPUBLISHED REPORT350
Comments:TRANSMISSIVITY AND STORATIVITY AVG. OF 3 MODELS USING MOENCH, HANTUSH (NO STOR.), AND COOPER-JACOB SOLUTION METHODS. AQUIFER THICKNESS REPORTED AS 1225 FT BY J HERR (UNABLE TO UPDATE DATABASE -CB)

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
OKF-82O
748251
1079459
COOPER-JACOB APPROXIMATION
119.4
32220
.0015
OKF-82O
748251
1079459
OTHER
119.4
4278
.0014
OKF-82O
748251
1079459
UNKNOWN
119.4
32320
.0013

Page generated at: 04-OCT-2025 06:39 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?