DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
AT STATION W-16972OKF-897508781036146

Start Test Date:09-MAY-1994 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):5638
Discharge Rate (gal/min):259Horizontal K (ft/day):28
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):680Storativity:.00007
Tested Interval Max. (ft BLS):882Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD J. HERR, UNPUBLISHED REPORT350
Comments:TRANSMISSIVITY AND STORATIVITY AVG. FROM 5 MODELS USING HANTUSH (W/STOR), MOENCH, THEIS, HANTUSH (NO STOR.), AND PAPADOPULOS-COOPER SOLUTION METHODS.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
OKF-89O1
750877
1036247
HANTUSH (1960)
200
5916
.00008
OKF-89O1
750877
1036247
HANTUSH-JACOB (1955)
200
5905
.000081
OKF-89O1
750877
1036247
OTHER
200
2743
.000023
OKF-89O1
750877
1036247
PADAPOLOUS
200
5992
.000077
OKF-89O1
750877
1036247
THEIS RECOVERY
200
5983
.000078

Page generated at: 04-OCT-2025 10:14 EDT