DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
REEDY CREEK IMPROVEMENT DISTRICT WWTP
ORF-60
467176
1470889
Start Test Date:
01-APR-2003 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
63686
Discharge Rate (gal/min):
2610
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
220
Storativity:
Tested Interval Max. (ft BLS):
715
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
235.14
Source
Reference
Citation Id
SOUTH FLORIDA WMD
HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM REEDY CREEK IMPROVEMENT DISTRICT ORANGE COUNTY, FLORIDA. NOVEMBER 2004.
211
Comments:
INTERVAL TEST #1 OF 2 SPECIFIC CAPACITY: 235 GPM/FT TDS: 134 MG/L
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
REEDY CREEK IMPROVEMENT DISTRICT WWTP
ORF-60
467176
1470889
Start Test Date:
26-NOV-2003 0000
Aquifer:
LOWER FLORIDAN AQUIFER (FZ1)
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
18428
Discharge Rate (gal/min):
1152
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1170
Storativity:
Tested Interval Max. (ft BLS):
1280
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
67.96
Source
Reference
Citation Id
SOUTH FLORIDA WMD
HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM REEDY CREEK IMPROVEMENT DISTRICT ORANGE COUNTY, FLORIDA. NOVEMBER 2004.
211
Comments:
INTERVAL TEST #2 OF 2 SPECIFIC CAPACITY: 68 GPM/FT TDS: 160 MG/L
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
REEDY CREEK IMPROVEMENT DISTRICT WWTP
ORF-60
467176
1470889
Start Test Date:
24-JUN-2003 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1930
Storativity:
Tested Interval Max. (ft BLS):
1970
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
58.7
Source
Reference
Citation Id
Comments:
PACKER TEST 1 OF 2 SPECIFIC CAPACITY: 58.7 GPM/FT TDS: 144 MG/L
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
REEDY CREEK IMPROVEMENT DISTRICT WWTP
ORF-60
467176
1470889
Start Test Date:
25-JUN-2003 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1510
Storativity:
Tested Interval Max. (ft BLS):
1540
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
1.5
Source
Reference
Citation Id
Comments:
PACKER TEST 2 OF 2 SPECIFIC CAPACITY: 1.5 GPM/FT TDS: 158 MG/L
Page generated at: 04-OCT-2025 10:09 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?