Start Test Date: | 16-JUN-2003 0000 | Aquifer: | FLORIDAN AQUIFER SYSTEM |
Test Type: | APT | Transmissivity (ft2/day): | 40650 |
Discharge Rate (gal/min): | 2000 | Horizontal K (ft/day): | |
Hours Pumped: | 72 | Vertical K (ft/day): | |
Tested Interval Min. (ft BLS): | 106 | Storativity: | .0024 |
Tested Interval Max. (ft BLS): | 650 | Leakance (1/day): | |
No. Monitored Wells: | | Specific Capacity (gpm/ft): | |