DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
OSF-70 AT NEPTUNE ROADOSF-705505091424601

Start Test Date:06-JUN-2008 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):29410
Discharge Rate (gal/min):900Horizontal K (ft/day):88
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):130Storativity:.00056
Tested Interval Max. (ft BLS):250Leakance (1/day):.25
No. Monitored Wells:5Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD ANDERSON, 2011. SFWMD TECHNICAL PUBLICATOIN WS-29339
Comments:LEAKANCE IS FROM ABOVE AND BELOW