DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Palmer Ranch Wellfield WUP 209638PALMERRPW1927921045869

Start Test Date:01-JAN-1989 0000Aquifer:MID-HAWTHORN AQUIFER
Test Type:APTTransmissivity (ft2/day):1163
Discharge Rate (gal/min):250Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):63Storativity:.000067
Tested Interval Max. (ft BLS):200Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Smally, Wellford & Nalven, 1989.
Comments:T & S values are avg. estimates; background water level monitored 2 weeks prior to test; 0.2" rainfall had negligible effect; no data corrections applied; used straight-line approxiamtion & distance-drawdown methods for analysis.: DATE = REPORT YEAR

Page generated at: 04-OCT-2025 03:55 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?