DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ENCON INJECTION WELLPB-1170936563942381

Start Test Date:18-FEB-1986 1000Aquifer:BOULDER ZONE
Test Type:APTTransmissivity (ft2/day):298128
Discharge Rate (gal/min):10025Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2839Storativity:
Tested Interval Max. (ft BLS):3505Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1986
Comments:T estimated greater than reported amount from specific injectivity, assumed = specific capacity based on method by Walton, 1970.



SitePumped WellX-Coord(ft)Y-Coord (ft)
ENCON INJECTION WELLPB-1170936563942381

Start Test Date:12-NOV-1985 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):561.9
Discharge Rate (gal/min):Horizontal K (ft/day):11.24
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2280Storativity:
Tested Interval Max. (ft BLS):2330Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1986
Comments:ANALYSIS METHOD: CEDERGREN (1977)



SitePumped WellX-Coord(ft)Y-Coord (ft)
ENCON INJECTION WELLPB-1170936563942381

Start Test Date:12-NOV-1985 0002Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):796.9
Discharge Rate (gal/min):Horizontal K (ft/day):3.79
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2360Storativity:
Tested Interval Max. (ft BLS):2570Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1986
Comments:ANALYSIS METHOD: CEDERGREN (1977)



SitePumped WellX-Coord(ft)Y-Coord (ft)
ENCON INJECTION WELLPB-1170936563942381

Start Test Date:12-NOV-1985 0003Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):4.89
Discharge Rate (gal/min):Horizontal K (ft/day):.1
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2740Storativity:
Tested Interval Max. (ft BLS):2790Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1986
Comments:ANALYSIS METHOD: CEDERGREN (1977)



SitePumped WellX-Coord(ft)Y-Coord (ft)
ENCON INJECTION WELLPB-1170936563942381

Start Test Date:12-NOV-1985 0004Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):489.7
Discharge Rate (gal/min):Horizontal K (ft/day):3.47
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2568Storativity:
Tested Interval Max. (ft BLS):2709Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1986
Comments:ANALYSIS METHOD: CEDERGREN (1977)

Page generated at: 04-OCT-2025 10:16 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?