DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS SITE 2PB-1575916679763421

Start Test Date:05-NOV-1986 0000Aquifer:BISCAYNE
Test Type:APTTransmissivity (ft2/day):31000
Discharge Rate (gal/min):318Horizontal K (ft/day):310
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):77Storativity:.0027
Tested Interval Max. (ft BLS):183Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY T.P. 89-4
Comments:Approximately 64 ft thickness of Biscayne within the tested section.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
PB-1575
916679
763421
COOPER-JACOB APPROXIMATION
30
31000

Page generated at: 28-SEP-2024 19:48 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?