DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS SITE 17PB-1607924446926546

Start Test Date:23-FEB-1987 0000Aquifer:BISCAYNE
Test Type:APTTransmissivity (ft2/day):13000
Discharge Rate (gal/min):332Horizontal K (ft/day):130
Hours Pumped:6Vertical K (ft/day):
Tested Interval Min. (ft BLS):50Storativity:
Tested Interval Max. (ft BLS):150Leakance (1/day):
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY T.P. 89-4
Comments:Approximately 16 ft thickness of Biscayne within the tested section.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
PB-1607
924446
926546
COOPER-JACOB APPROXIMATION
0
5
17000
PB-1608
924300
926604
COOPER-JACOB APPROXIMATION
30
5.66
15000

Page generated at: 04-OCT-2025 06:35 EDT