DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PALM BEACH COUNTY WATER UTIL. DEPT. WTP NO. 3- FAS ASR
PB-1763
938733
782345
Start Test Date:
30-JAN-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
Discharge Rate (gal/min):
508
Horizontal K (ft/day):
Hours Pumped:
24
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
985
Storativity:
Tested Interval Max. (ft BLS):
1200
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Data compiled in USGS WRIR 02-4036, data originally from, REESE, R, USGS WRIR 02-4036, 2002
Comments:
SPECIFIC CAPACITY: 390-306 GALLONS/MIN/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PALM BEACH COUNTY WATER UTIL. DEPT. WTP NO. 3- FAS ASR
PB-1763
938733
782345
Start Test Date:
25-FEB-1999 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
8943
Discharge Rate (gal/min):
530
Horizontal K (ft/day):
Hours Pumped:
1.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
Storativity:
Tested Interval Max. (ft BLS):
1155
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
PALM BEACH COUNTY WATER UTILITIES DEPARTMENT, MARCH 2003, WATER TREATMENT PLANT NO. 3 MULTIPURPOSE FLORIDAN AQUIFER STORAGE AND RECOVERY WELL PBCWUD PROJECT NO. 96-37 WELL CONSTRUCTION REPORT AND OPERATIONAL TESTING REQUEST
Comments:
TRANSMISSIVITY WAS ESTIMATED DUE TO LIMITED AMOUNT OF DATA FOR ASR ZONE. THE 72-HOUR APT WAS ABSENT. THE SPECIFIC CAPACITY RATES RANGED FROM 25.2 GPM/FT AT 2100 GPM TO 47.8GPM/FT AT 530 GPM. WELL WAS PUMPED FOR 1.5 HOURS AT EACH RESPECTIVE PUMPING RATE (530 GPM, 920 GPM, 1610 GPM & 2100 GPM).
Page generated at: 04-OCT-2025 03:56 EDT